If you attend BICSI certification RCDD exams, your choosing IT-Tests.com is to choose success! I wish you good luck.
When you select to use IT-Tests's products, you have set the first foot on the peak of the IT industry and the way to your dream is one step closer. The practice questions of IT-Tests.com can not only help you pass BICSI certification RCDD exam and consolidate your professional knowledge, but also provide you one year free update service.
IT-Tests.com not only have a high reliability, but also provide a good service. If you choose IT-Tests, but don't pass the exam, we will 100% refund full of your cost to you. IT-Tests.com also provide you with a free update service for one year.
About the RCDD exam certification, reliability can not be ignored. RCDD exam training materials of IT-Tests.com are specially designed. It can maximize the efficiency of your work. We are the best worldwide materials provider about this exam.
If you are still hesitating whether to select IT-Tests, you can free download part of our exam practice questions and answers from IT-Tests.com website to determine our reliability. If you choose to download all of our providing exam practice questions and answers, IT-Tests.com dare 100% guarantee that you can pass BICSI certification RCDD exam disposably with a high score.
There are a lot of sites provide the BICSI RCDD exam certification and other training materials for you . IT-Tests.com is only website which can provide you BICSI RCDD exam certification with high quality. In the guidance and help of IT-Tests.com, you can through your BICSI RCDD exam the first time. The questions and the answer provided by IT-Tests.com are IT experts use their extensive knowledge and experience manufacturing out . It can help your future in the IT industry to the next level.
Exam Code: RCDD
Exam Name: BICSI (Registered Communications Distribution Designer )
Some sites provide BICSI RCDD exam study materials on the Internet , but they do not have any reliable guarantee. Let me be clear here a core value problem of IT-Tests.com . All BICSI exams are very important. In this era of rapid development of information technology, IT-Tests.com just questions provided by one of them. Why do most people choose IT-Tests.com? This is because the exam information provided by IT-Tests.com will certainly be able to help you pass the exam. Why? Because it provides the most up-to-date information, which is the majority of candidates proved by practice.
RCDD (Registered Communications Distribution Designer ) Free Demo Download: http://www.it-tests.com/RCDD.html
NO.1 Which of the following is the Cable Modem (Cable-TV) Working Group?
A. IEEE 802.9
B. IEEE 802.11
C. IEEE 802.14
D. IEEE 802.3
Answer: C
BICSI exam prep RCDD RCDD
NO.2 Between the late 60's and until 1984, what was the service that was to help architects
and engineers better design and implement pathways and spaces in commercial
buildings for telephone communications?
A. BICS
B. AT&T
C. CREDFACS
D. GTE
E. BICSI
Answer: A
BICSI RCDD exam dumps RCDD RCDD
NO.3 In buildings that will contain the telecommunications systems, NEC requirements
address the adequate electrical environment for reliable and error-free operation of
the installed equipment.
A. False
B. True
Answer: A
BICSI RCDD exam dumps RCDD RCDD RCDD answers real questions
NO.4 For design purposes, which of the following would be the typical size range of a
4-pair 100 ohm UTP or ScTP (FTP) cable?
A. .50 in to .75 in
B. .14 in to .25 in
C. .31 in to .43 in
D. .11 in to .18 in
Answer: B
BICSI RCDD answers real questions RCDD RCDD
NO.5 Which of the following is the standard for "Recommended Practice for Installation
Design and Installation of Valve Regulated Lead-Acid Storage Batteries for
Stationary Applications"?
A. ANSI/IEEE C62.41
B. ANSI/IEEE C62.45
C. ANSI/IEEE P1188-1996
D. ANSI/IEEE P1187-1996
Answer: D
BICSI answers real questions RCDD demo RCDD RCDD exam
NO.6 Which of the following should be used as a guideline for estimating space
requirements of optical fiber and coaxial cable cross-connections in a TR?
A. 3 sq. in. for each fiber pair to be patched or cross-connected.
B. 2 sq. in. for each fiber pair to be patched or cross-connected.
C. 4 sq. in. for each fiber pair to be patched or cross-connected.
D. 1 sq. in. for each fiber pair to be patched or cross-connected.
Answer: B
BICSI study guide RCDD RCDD
NO.7 Which of the following is the Standard for the Installation of Lightning Protection
Systems?
A. NFPA-780
B. NFPA-70
C. NFPA-72
D. NFPA-75
Answer: A
BICSI RCDD braindump RCDD demo RCDD
NO.8 In an "underfloor duct system", the distribution ducts carry cables from the TR to
the feeder ducts.
A. False
B. True
Answer: A
BICSI answers real questions RCDD test questions RCDD practice test RCDD
NO.9 NRZ is the acronym for which of the following?
A. Non-return to zero.
B. Nominal return zone.
C. Network registration zone.
D. Normal return zone.
Answer: A
BICSI original questions RCDD certification RCDD RCDD RCDD certification
NO.10 ________is the total opposition (resistance, capacitance, and inductance) a circuit,
cable, or component offers to the flow of alternating current.
A unit of measure expressed in ohms.
Answer: Impedance
BICSI RCDD RCDD RCDD exam prep RCDD
NO.11 In what year was the TIA formed?
A. 1985
B. 1965
C. 1958
D. 1956
Answer: A
BICSI RCDD test answers RCDD RCDD RCDD
NO.12 The ability of a device, equipment, or system to perform without degradation in the
presence of an electromagnetic disturbance is called what?
A. Electromagnetic immunity.
B. Electromagnetic compatibility.
C. Electromagnetic induction.
D. Electromagnetic disturbance.
Answer: A
BICSI questions RCDD RCDD pdf RCDD exam simulations RCDD
NO.13 Which of the following is the international standard for premises cabling?
A. ISO/IEC 18010
B. ISO/IEC 11801
Answer: B
BICSI answers real questions RCDD pdf RCDD RCDD study guide
NO.14 Distribution cable is that part of the loop that connects the customer location to the
customer feeder cable.
A. True
B. False
Answer: A
BICSI RCDD RCDD
NO.15 The CEC is revised every four years.
A. True
B. False
Answer: A
BICSI original questions RCDD certification RCDD original questions RCDD exam prep
NO.16 A product is listed after it successfully completes a series of which of the following
test?
A. Mechanical
B. Regulatory codes
C. Electrical
D. Thermal
Answer: ACD
BICSI RCDD answers real questions RCDD original questions RCDD
NO.17 What is the standard floor space allocation used in an office environment for one
individual work area?
A. 100 square feet.
B. 50 square feet.
C. 150 square feet.
D. 75 square feet.
Answer: A
BICSI answers real questions RCDD original questions RCDD exam dumps
NO.18 The inadvertent transposition of two conductors of separate pairs is called what?
A. Twisted pair
B. Transposed pairs
C. Reversed pair
D. Split pair
Answer: D
BICSI RCDD exam simulations RCDD study guide RCDD
NO.19 A "wye" is a power system in which only one point is grounded.
A. False
B. True
Answer: B
BICSI test answers RCDD RCDD test questions
NO.20 ANSI/TIA/EIA-758 is the standard for which of the following?
A. Customer-Owned Outside Plant Telecommunications Cabling Standard.
B. Technical Specifications for 100 Ohm Screened Twisted Pair Cabling.
C. Propagation Delay and Delay Skew Specifications for 100-Ohm 4-Pair Cable.
D. Residential Telecommunications Cabling Standard.
Answer: A
BICSI exam dumps RCDD RCDD RCDD
Those who want to prepare for the IT certification exam are helpless. But they have to do it. So they have restless state of mind. However, With IT-Tests.com BICSI RCDD exam training materials, the kind of mentality will disappear. With IT-Tests.com's BICSI RCDD exam training materials, you can be brimming with confidence, and do not need to worry the exam. Of course, you can also face the exam with ease. This is not only psychological help, but more importantly, it allows you to pass the exam and to help you get a better tomorrow.