There are a lot of sites provide the HP HP0-500 exam certification and other training materials for you . IT-Tests.com is only website which can provide you HP HP0-500 exam certification with high quality. In the guidance and help of IT-Tests.com, you can through your HP HP0-500 exam the first time. The questions and the answer provided by IT-Tests.com are IT experts use their extensive knowledge and experience manufacturing out . It can help your future in the IT industry to the next level.
If you choose IT-Tests, success is not far away for you. And soon you can get HP certification HP0-500 exam certificate. The product of IT-Tests.com not only can 100% guarantee you to pass the exam, but also can provide you a free one-year update service.
There are different ways to achieve the same purpose, and it's determined by what way you choose. A lot of people want to pass HP certification HP0-500 exam to let their job and life improve, but people participated in the HP certification HP0-500 exam all knew that HP certification HP0-500 exam is not very simple. In order to pass HP certification HP0-500 exam some people spend a lot of valuable time and effort to prepare, but did not succeed.
If you want to through the HP HP0-500 certification exam to make a stronger position in today's competitive IT industry, then you need the strong expertise knowledge and the accumulated efforts. And pass the HP HP0-500 exam is not easy. Perhaps through HP HP0-500 exam you can promote yourself to the IT industry. But it is not necessary to spend a lot of time and effort to learn the expertise. You can choose IT-Tests.com's HP HP0-500 exam training materials. This is training product that specifically made for IT exam. With it you can pass the difficult HP HP0-500 exam effortlessly.
With IT-Tests.com's HP HP0-500 exam training materials, you can get the latest HP HP0-500 exam questions and answers. It can make you pass the HP HP0-500 exam. HP HP0-500 exam certification can help you to develop your career. IT-Tests.com's HP HP0-500 exam training materials is ensure that you fully understand the questions and issues behind the concept. t can help you pass the exam easily.
The HP0-500 examination certification, as other world-renowned certification, will get international recognition and acceptance. People around the world prefer HP0-500 exam certification to make their careers more strengthened and successful. In IT-Tests.com, you can choose the products which are suitable for your learning ability to learn.
Exam Code: HP0-500
Exam Name: HP (HP ProLiant Server Maintenance)
Free One year updates to match real exam scenarios, 100% pass and refund Warranty.
Total Q&A: 200 Questions and Answers
Last Update: 2013-11-28
You can free download part of practice questions and answers about HP certification HP0-500 exam to test our quality. IT-Tests.com can help you 100% pass HP certification HP0-500 exam, and if you carelessly fail to pass HP certification HP0-500 exam, we will guarantee a full refund for you.
HP0-500 (HP ProLiant Server Maintenance) Free Demo Download: http://www.it-tests.com/HP0-500.html
NO.1 .Which utility is assists in planning and configuring Compaq racks?
A. RackManager
B. RackAssistant
C. RackIntegrator
D. RackBuilder Pro
Answer: D
HP HP0-500 HP0-500 questions HP0-500 exam
NO.2 .What are the best sources for the latest versions of Rompaqs and Softpaqs? Select two.
A. Compaq ResourcePaq
B. SmartStart
C. HP/Compaq website
D. QuickFind2000
E. OS ServicePaq
Answer: B,C
HP practice test HP0-500 HP0-500 HP0-500 HP0-500
NO.3 .What can Compaq Diagnostics reliably test?
A. Compaq Insight Manager (CIM) agents
B. system ROM BIOS compatibility
C. DAT tape drive read/write function
D. non-Compaq SCSI controller
Answer: C
HP HP0-500 braindump HP0-500 HP0-500
NO.4 .What is used to disable a Compaq server serial port?
A. Compaq Insight Manager
B. System Board Switch
C. System Configuration Utility
D. Nothing, as it is disabled by default
Answer: C
HP braindump HP0-500 exam dumps HP0-500 demo HP0-500 exam dumps HP0-500
NO.5 .Which Compaq server component is covered under prefailure warranty?
A. DIMM memory
A. hard disk controller
B. recovery server option
C. network interface controller
Answer: A
HP test answers HP0-500 HP0-500 HP0-500 HP0-500 HP0-500 test questions
NO.6 .What problem is indicated if the server powers up with no video and an audible POST error?
A. memory module not seated
B. monitor signal cable not connected
C. intermittent memory parity errors
D. monitor in power saver mode
Answer: A
HP dumps HP0-500 original questions HP0-500 HP0-500 practice test
NO.7 .While running Diagnostics on your ProLiant server, you receive an error code: 6092. What should you
do?
A. Replace network card.
B. Replace disk controller.
C. Connect external loopback cable.
D. Place network card in a different slot.
Answer: C
HP HP0-500 practice test HP0-500 HP0-500 test answers HP0-500 practice test
NO.8 .Which action is required to safely replace non hot-pluggable components in servers with redundant
hot-pluggable power supplies?
A. Depress server On/Off switch from front panel.
B. Ensure DC LED indicator on the hot-pluggable power supply is inactive.
C. Remove AC power cord from the primary hot-pluggable power supply.
D. Remove AC power cords from all hot-pluggable power supplies.
Answer: D
HP demo HP0-500 HP0-500
NO.9 .What is the likely cause of rack instability?
A. more than one component simultaneously extended
B. UPS installed at the bottom of the rack
C. side panels not installed
D. missing blanking panels
Answer: A
HP test answers HP0-500 HP0-500 HP0-500
NO.10 .Which product reports prefailure on all Compaq SMART hard drives?
A. CIM
B. RBSU C. ACU D. SCU
Answer: A
HP HP0-500 exam HP0-500
NO.11 .What do Compaq hot-pluggable power supplies have that traditional power supplies do not?
A. higher current
B. higher voltage
C. microcontroller Self-Test
D. power Monitor Port
Answer: C
HP braindump HP0-500 HP0-500 certification HP0-500 exam
NO.12 .Where should the server Feature Board be installed in Compaq servers?
A. A designated slot
B. Any PCI 64-bit slot
C. Any extended slot
D. An EISA slot
Answer: A
HP HP0-500 braindump HP0-500 certification HP0-500 dumps HP0-500
NO.13 .A defective processor is replaced in a Compaq server. The 212 "System Processor Failed" POST
error will not go away. What action can be performed?
A. Erase NVRAM to clear the Health Log.
B. Run Diagnostics on memory.
C. Replace hot-pluggable power supply.
D. Replace Memory Expansion Board.
Answer: A
HP HP0-500 HP0-500
NO.14 .How is a redundant Xeon server PPM identified?
A. one processor installed
B. two processors installed
C. fully populated PPM circuit board
D. half populated PPM circuit board
Answer: C
HP study guide HP0-500 HP0-500 test questions HP0-500 certification HP0-500 HP0-500
NO.15 .What action is recommended if the Server Health Driver consistently reports a correctable memory
error in the same location?
A. Run ERASE utility to clear the location.
B. Schedule downtime and replace memory.
C. This is normal and can be ignored.
D. Mark "repaired" in Insight Manager.
Answer: B
HP HP0-500 study guide HP0-500 study guide
NO.16 .What is the available array space after grouping six 4GB hard drives using Advanced Data Guarding?
A. 12GB
B. 16GB
C. 20GB
D. 24GB
Answer: B
HP HP0-500 HP0-500
NO.17 .What enables remote server management and control regardless of the operating system or condition
of the server?
A. CIM (Compaq Insight Manager)
B. SCU (System Configuration Utility)
C. Remote Utilities (from system Diagnostics menu)
D. RILOE (Remote Insight Light Out Edition option)
Answer: D
HP HP0-500 HP0-500 HP0-500 answers real questions
NO.18 .A hard drive fails on a system with an on-line spare. When is it recommended that the failed drive be
replaced?
A. upon discovery of the failure
B. upon completion of rebuild of on-line spare
C. not needed, failed drive will perform self-repair
D. any time before rebuild of online spare is complete
Answer: B
HP original questions HP0-500 HP0-500 pdf
NO.19 .Which resources could be used to help isolate correctable memory errors?
A. SSD and DAAD
B. ACU and SmartStart
C. Server Health Logs and Integrated Management Log
D. QRG (Quick Reference Guide) and Inspect
Answer: C
HP HP0-500 certification HP0-500 questions HP0-500 practice test HP0-500 pdf HP0-500
NO.20 .After a field engineer adds a second array controller to the server, the operating system does not boot .
What is the likely cause of the problem?
A. incorrect jumper settings
B. incorrect slot order
C. array controller boot order D. interrupt conflicts
Answer: C
HP certification HP0-500 HP0-500 dumps HP0-500 exam simulations
NO.21 Which component failure will cause a Compaq server to reset but not power up?
A. IMD
B. PPM
C. DIMM
D. CPU
Answer: B
HP exam dumps HP0-500 HP0-500 exam prep HP0-500 HP0-500
NO.22 .On a ProLiant 450 MHz processor server, Level 2 cache is logging errors. Which item should be
replaced?
A. Cache Memory Stick
B. System I/O Board
C. CPU/Processor Module
D. Riser Card
Answer: C
HP HP0-500 HP0-500 questions HP0-500 study guide HP0-500
NO.23 .Which diagnostic mode tests individual components of a server?
A. Intermediate
B. Automatic
C. QuickCheck
D. Prompted
Answer: D
HP HP0-500 HP0-500 test answers
NO.24 .Which step must be performed when upgrading a customer's ProLiant server from a Pentium II Xeon
to Pentium III Xeon processor?
A. Flash ROM before replacing processors.
B. Ensure all processors have the same frequency and cache size.
C. Mix cache sizes in pairs for sockets 1 and 3.
D. Upgrade terminator boards for all four sockets.
Answer: A
HP test answers HP0-500 HP0-500 HP0-500 test questions
NO.25 .Which Compaq utility is used to configure Online Spare memory?
A. Rapid Raid Utility
B. Raid Builder for AMP
C. ROM-based Setup Utility
D. SmartStart
Answer: C
HP HP0-500 HP0-500 test answers HP0-500 demo HP0-500 exam
NO.26 .When servicing a customer's system, what is the proper sequence to remove power to the server and
any external storage subsystems?
A. external storage systems first, then server
B. server first, then the external storage systems
C. UPS, then the server
D. external storage first, then the UPS
Answer: B
HP pdf HP0-500 HP0-500 test answers HP0-500 HP0-500 practice test
NO.27 .Which network interface controller configuration can support redundant NICs?
A. one dual-port fast Ethernet network controller
B. one 16/4 token ring network controller connected to a managed hub
C. one fast Ethernet network controller connected to a second server
D. one fast Ethernet network controller connected to a router
Answer: A
HP exam simulations HP0-500 exam prep HP0-500 HP0-500 exam simulations
NO.28 .What capability do fans have in some hot-pluggable power supplies?
A. variable RPM, depending on thermal sensor readings
B. hot plug fan replacement
C. dual-power inputs for redundancy
D. redundant power supply fans
Answer: A
HP practice test HP0-500 test answers HP0-500 HP0-500 HP0-500 demo
NO.29 .What is the first required action to safely remove an adapter from a Compaq PCI hot-pluggable slot?
A. Just remove the card.
B. Power down the slot to remove the card.
C. Power down the server to remove the card.
D. Install the new card in another slot.
Answer: B
HP HP0-500 HP0-500 pdf
NO.30 .What is the advantage of having an online spare as part of a SMART array configuration?
A. The drive can be used for temporary data storage until another drive fails.
B. The array will not lose its fault tolerance in case of a single drive failure.
C. You always have a spare drive available to physically put in place of a failed drive without having to
order a spare drive.
D. You can load balance across the array.
Answer: B
HP questions HP0-500 practice test HP0-500 exam dumps HP0-500 HP0-500
IT-Tests.com offer the latest 000-124 Questions & Answers and high-quality 000-614 PDF Practice Test. Our MB6-871 VCE testing engine and 000-277 study guide can help you pass the real exam. High-quality LOT-440 Real Exam Questions can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.
Article Link: http://www.it-tests.com/HP0-500.html
没有评论:
发表评论